Evap. system vapor pressure
Last reviewed 2026-08-31
Mode 01 · PID 32 (decimal 50)
Description
Evaporative system vapour pressure. AB is two’s complement signed.
- PID number
- 32 · 50
- Unit
- Pa
- Range
- -8192 … 8191.75
- Data bytes
- 2
- Formula
- ((A*256)+B)/4 (signed)
- Also valid as Mode 02 freeze-frame data (same PID number, snapshot at last DTC).
Defined by SAE J1979 / ISO 15031-5. Public index — not a substitute for the paid SAE document.
Sources
Provenance for this page. Official standards outrank community notes. See the confidence policy.
Official standard · high trust
SAE J1979 / ISO 15031-5 Mode 01 PID formulas (public index)
J1979 public PID index: 01 32