Skip to content
OBD2 PID Knowledge
Open menu

In-use performance tracking (spark ignition)

Last reviewed 2026-08-31

Mode 09 · PID 08 (decimal 8)

Description

In-use Monitor Performance Ratio (IUMPR) for spark engines: paired numerator/denominator counters (OBDCOND, IGNCNTR, CATCOMP1, CATCOND1, O2SCOMP1, …). See decode table on this PID page.

PID number
08 · 8
Unit
Range
Data bytes
4
Formula
Numerator/denominator pairs (CAT, O2, EGR, EVAP, AIR, …)

Field sequence

Ordered sub-fields inside the PID payload (each pair is typically two bytes).

# Mnemonic Meaning
1 OBDCOND OBD monitoring conditions encountered

Denominator: how often OBD monitoring conditions were met.

2 IGNCNTR Ignition counter

Engine-start / ignition counter for IUMPR context.

3 CATCOMP1 Catalyst monitor completions — bank 1

Numerator: catalyst monitor completed on bank 1.

4 CATCOND1 Catalyst monitor conditions — bank 1

Denominator: conditions met for bank 1 catalyst monitor.

5 CATCOMP2 Catalyst monitor completions — bank 2

Numerator: catalyst monitor completed on bank 2.

6 CATCOND2 Catalyst monitor conditions — bank 2

Denominator: conditions met for bank 2 catalyst monitor.

7 O2SCOMP1 O2 sensor monitor completions — bank 1

Numerator: O2 monitor completed on bank 1.

8 O2SCOND1 O2 sensor monitor conditions — bank 1

Denominator: conditions met for bank 1 O2 monitor.

9 O2SCOMP2 O2 sensor monitor completions — bank 2

Numerator: O2 monitor completed on bank 2.

10 O2SCOND2 O2 sensor monitor conditions — bank 2

Denominator: conditions met for bank 2 O2 monitor.

11 EGRCOMP EGR monitor completions

Numerator: EGR monitor completed.

12 EGRCOND EGR monitor conditions

Denominator: conditions met for EGR monitor.

13 AIRCOMP Secondary air monitor completions

Numerator: AIR monitor completed.

14 AIRCOND Secondary air monitor conditions

Denominator: conditions met for AIR monitor.

15 EVAPCOMP EVAP monitor completions

Numerator: evaporative leak monitor completed.

16 EVAPCOND EVAP monitor conditions

Denominator: conditions met for EVAP monitor.

17 SO2SCOMP1 Secondary O2 monitor completions — bank 1

Numerator: secondary O2 monitor completed on bank 1.

18 SO2SCOND1 Secondary O2 monitor conditions — bank 1

Denominator: conditions met for secondary O2 monitor on bank 1.

19 SO2SCOMP2 Secondary O2 monitor completions — bank 2

Numerator: secondary O2 monitor completed on bank 2.

20 SO2SCOND2 Secondary O2 monitor conditions — bank 2

Denominator: conditions met for secondary O2 monitor on bank 2.

Defined by SAE J1979 / ISO 15031-5. Public index — not a substitute for the paid SAE document.

Sources

Provenance for this page. Official standards outrank community notes. See the confidence policy.

Was this page useful?

This does not change the catalog. A curator reads the vote. For a sourced PID or a correction, submit a tip.